LocationHome » News Center » News » Industry information » WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

Contact us

  • 2/F,2nd Building, Sunlink International Machinery City, Chencun Town, Shunde District, Foshan 528313, Guangdong,China.
  • sales@waltek.com.cn
  • +86-757-2381 1398
  • +86-757-2381 1398

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

Release date:May 13,2020 Source:WALTEK
WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113
Pageviews:-
In October 2018, the 11th edition of the CSA113 standard will replace the tenth edition. As a standard for fans and ventilation, the CSA113 standard immediately became a hot spot in the industry.

In October 2018, the 11th edition of the CSA113 standard will replace the tenth edition. As a standard for fans and ventilation, the CSA113 standard immediately became a hot spot in the industry.

WALTEK This article interprets the main hotspots of the CSA113 standard, hoping to enable enterprise customers and manufacturers to understand the new standards more clearly and prepare for relevant testing and certification in a timely manner.

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

And this update replaces an important message that CSA113 removes the description and requirements of ceiling fans, table fans, floor fans, box fans, cooling fans, bench fans, partition fans, duct fans, and hoods. These are deleted. The product will be verified by another standard: the fan type product will be changed to CAN/CSA-C22.2 No. 60335-2-80.

What are the obvious similarities and differences between CSA113 and CSA60335-2-80?

1, the temperature rise part

The temperature rise of the CSA113 requires a voltage test of 104V & 127V; the CSA60335-2-80 is tested at 0.94 times and 1.06 times the rated voltage.

2, the material part

The original CSA113 requires 5VA material to be used under the exposed live parts; however, CSA60335-2-80 does not have this clause.

3, internal line requirements

The original CSA113 standard requires that the internal line be at least 18 AWG except for the 150 mm line of the motor. The internal line has at least 18 AWG; however, CSA 60335-2-80 does not.

4, structural requirements

CSA60335-2-80 adds information about the insulation system of the product, requiring only a basic insulated fan structure, and the metal housing needs to be grounded.

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

5, information problems

CSA60335-2-80 requires that if the fan environment is tropical, the label of the product needs to be T. The temperature rise test needs to be carried out according to the T value as the ring temperature.

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

6, increased testing

CSA60335-2-80 requires an electronic fan to be tested for plug discharge, which requires a voltage reduction of less than 34V in 1 second.

WALTEK Analysis The latest version of the fan product CSA60335-2-80 is compared with the original version CSA113

The Waltek Test Group was founded in 2003 and is headquartered in Shenzhen. It is an independent and professional third-party testing and certification organization. It has three major strength brands: Waltek-Test, HCT-Test and SEM-Test, as well as various branches in Foshan, Dongguan, Zhongshan, Suzhou, Ningbo, Hunan and Hong Kong. The service network covers the whole country.
【Tag of this article】:WALTEK
【Editor】:WALTEKall rights reserved:http://www.waltekgroup.comPlease indicate the source

Comment Reading

Users' hot comments

  • 验证码